J&D MFG | COMMERCIAL/INDUSTRIAL VENTILATION
A3 - J&D TITAN II - 55" | Exhaust Fan 32,500 CFM, 1 & 3 Phase 3 Blade GLV, 1 1/2 & 2 HP Energy Efficient, 115/230v, & 208/230/460v, VFD Comp, Multi Models | VTW55G3CN23 (CLICK TO VIEW CUT SHEET & DETAILS) (CALL FOR FREE EXPERT ADVICE & PRICING)
- SKU:
- VTW55G3CN23
- Weight:
- 150.00 LBS
Description
Titan II 55" Exhaust Fans to - 32,500 CFM, Single & 3 Phase, 1 1/2 & 2 HP, 115/230v, 230/460v & 208/230/460v Models | VFD Compatible
Features
• Dual damper door design tightly seals to keep out the elements
• 1½ or 2 HP single or three phase high-efficiency motor
• Heavy-duty H-frame from J&D Manufacturing is our largest high-performance damper door fan. The housing has been re-engineered to offer a heavy-duty H-frame and a more compact depth. The dual damper door now boasts an even tighter seal to keep out the elements. Many new models, all containing single- and three-phase high-efficiency motors, meet all types of building ventilation needs.
Features
• Dual damper door design tightly seals to keep out the elements
• 1½ or 2 HP single or three phase high-efficiency motor
• Heavy-duty H-frame & Galvanized Damper Door Fan
Durable 18-gauge housing
Additional Information
How To Size Fan & Shutters System?
- First thing is to determine is the amount of air required. This is stated in CFM (Cubic Feet of Air per Minute). In addition, the required Air Changes Per Hour (ACH). A Greenhouse requires 60-120 ACH's depending on location and weather conditions.
- The following formula to determine the CFM's and ACH's required for your greenhouse:
CFM = Width x Length x Height
Example: Greenhouse 12' wide X 40' long X 12' High requires 9,600 CFM at 60 ACH, 14,400 CFM at 90 ACH and 19,200 CFM at 120 ACH. - Review the above table. Select the appropriate combination of fan(s) to achieve the necessary CFM rating and ACH. Be sure to match the total CFM output for your exhaust fan(s) to the CFM ratings for your Inlet Shutters. Below are examples of end wall to end wall and side wall to side wall ventilation. Call 888-849-1233 for Free Expert Advice.
2 Reviews
-
Seafood Processing Plant
We need to ventilate but yet keep cool our Seafood processing plant. We selected the Titans due to the air tight damper doors. Ventilate and seal very well.
-
Poultry Farm Ventilation
We chose the Titan II exhaust fans to update our old fans in our Poultry farm. Satisfied with results.