A2 - J&D WM LIGHT DEPRIVATION EXHAUST FANS 24", 30", 36", 42", 50" & 55" - 26,931 CFM | 115/230v & 3-Phase 208/230/460v | GREENHOUSE, FLOWER, CANNABIS, ETC. | VF553GGLT3 (CLICK TO VIEW CUT SHEET & DETAILS) (CALL FOR FREE EXPERT ADVICE & PRICING)

(12 reviews) Write a Review
SKU:
VF50GGLT3
Weight:
110.00 LBS
  • J&D WM LIGHT DEPRIVATION EXHAUST FANS  24", 30", 36", 42" & 50"  (Back view) Call for FREE Expert Advice |  Factory Fans Direct 888-849-1233
  • &D WM LIGHT DEPRIVATION EXHAUST FANS  24", 30", 36", 42" & 50"  (Front View) Call for FREE Expert Advice |  Factory Fans Direct 888-849-1233
  • Exterior View | The following are pictures of a 100,000 sq ft  Greenhouse that Factory Fans Direct designed and recommended the required ventilation. Eighty Eight  50" J&D Light Dep Exhaust Fans with Light Traps were utilized.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Interior View | The following are pictures of a 100,000 sq ft  Greenhouse that Factory Fans Direct designed and recommended the required ventilation. Eighty Eight  50" J&D Light Dep Exhaust Fans with Light Traps were utilized.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Exterior View | The following are pictures of a 100,000 sq ft  Greenhouse that Factory Fans Direct designed and recommended the required ventilation. Eighty Eight  50" J&D Light Dep Exhaust Fans with Light Traps were utilized.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Interior View | The following are pictures of a 100,000 sq ft  Greenhouse that Factory Fans Direct designed and recommended the required ventilation. Eighty Eight  50" J&D Light Dep Exhaust Fans with Light Traps were utilized.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Interior View | The following are pictures of a 100,000 sq ft  Greenhouse that Factory Fans Direct designed and recommended the required ventilation. Eighty Eight  50" J&D Light Dep Exhaust Fans with Light Traps were utilized.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Interior View | The following are pictures of a 100,000 sq ft  Greenhouse that Factory Fans Direct designed and recommended the required ventilation. Eighty Eight  50" J&D Light Dep Exhaust Fans with Light Traps were utilized.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Interior View | The following are pictures of a 100,000 sq ft  Greenhouse that Factory Fans Direct designed and recommended the required ventilation. Eighty Eight  50" J&D Light Dep Exhaust Fans with Light Traps were utilized.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Interior View | The following are pictures of a 100,000 sq ft  Greenhouse that Factory Fans Direct designed and recommended the required ventilation. Eighty Eight  50" J&D Light Dep Exhaust Fans with Light Traps were utilized.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Interior View | The following are pictures of a 100,000 sq ft  Greenhouse that Factory Fans Direct designed and recommended the required ventilation. Eighty Eight  50" J&D Light Dep Exhaust Fans with Light Traps were utilized.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Exterior View | The following are pictures of a 25'x100' Greenhouse with  50" J&D Light Dep Exhaust Fans with Light Traps.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • Interior View | The following are pictures of a 25'x100' Greenhouse with  50" J&D Light Dep Exhaust Fans with Light Traps.  Call Factory Fans Direct at 888-849-1233 for free expert advice and discounts.
  • The following is a diagram of end wall to end wall ventilation.  Recommended  air flow is 60-120 Air Changes per Hour (ACH's).  Call Factory Fans Direct at 888-849-1233 for Free Expert Advice and discounts.
  • The following is a diagram of side to side wall ventilation.  Recommended  air flow is 60-120 Air Changes per Hour (ACH's).  Call Factory Fans Direct at 888-849-1233 for Free Expert Advice and discounts.
Call 888-849-1233 for Free Expert Advice, Cut Sheet and Factory Direct Pricing

Description

J&D WM Light Deprivation Exhaust Fans 24", 30", 36", 42", 50" & 55" | Greenhouse Cannabis & Flower | Complete with Light Trap or Without Light Trap/Add Your Own (New 55" in Single & 3-Phase to 26,931 CFM's)

Using light deprivation to control plant growth and blooming is a trending strategy for short-day plants, such as cannabis and poinsettias. Without proper ventilation during the light deprivation stage, heat, mold, and disease can quickly destroy your crop, setting you back a whole season. J&D's WM Light Dep Exhaust Fan is a crucial piece of your greenhouse light deprivation system for healthy, robust, and profitable blooms.
 
 
  • Allows for bigger, higher quality, larger profit flowers
  • Full range of sizes, even ones for small greenhouses
  • Test data is for fan with light trap, enabling dependable and accurate air exchange calculations
  • Fan with light trap mounts flush to the interior of the building, freeing up valuable space and eliminating a protruding ledge
    • 1.5 million: 1 light reduction factor
    • Fan comes assembled, light trap comes easy-to-assemble, install, and remove for cleaning/maintenance
    • Housing is durable, corrosion resistant, 18 gauge galvanized steel for long life
    • Precision balanced prop for efficiency, extended fan life, and reduced noise
    • Choose standard motor or Gold Star Motor
    • VF24DMLT1 VF30DMLT1 VF36GGLT1 VF42GGLT1 VF50GGLT1 VF24DMLT3 VF30DMLT3 VF36GGLT3 VF42GGLT3 VF50GGLT3 VF24DMLT1-GS VF30DMLT1-GS VF24DMLT3-GS VF30DMLT3-GS 
     
     Specifications

    Standard/Belt Drive Motor

    Model No.SizePhaseSpeedCFM @0.10" SPCFM/Watt @0.10" SPDriveProp
    VF24DMLT1 24" 1 1 4,267 10.6 Direct 3-Alm
    VF24DMLT3 24" 3 1 4,457 10.7 Direct 3-Alm
    VF30DMLT1 30" 1 1 5,216 11.0 Direct 3-Alm
    VF30DMLT3 30" 3 1 6,259 12.1 Direct 3-Alm
    VF36GGLT1 36" 1 1 10,948 9.4 Belt 4-Glv
    VF36GGLT3 36" 3 1 11,044 9.9 Belt 4-Glv
    VF42GGLT1 42" 1 1 13,064 10.4 Belt 3-Glv
    VF42GGLT3 42" 3 1 13,957 10.4 Belt 3-Glv
    VF50GGLT1 50" 1 1 19,717 10.5 Belt 3-Glv
    VF50GGLT3 50" 3 1 22,038 10.1 Belt 3-Glv
     
     VF55GGLT1  55"   Single Phase 25,404 CFM | New Call 888-849-1233 for Details
     VF55GGLT3  55"   Three Phase  26,931 CFM | New Call 888-849-1233 for Details

    Gold Star Motor

    Model No.SizePhaseSpeedCFM @0.10" SPCFM/Watt @0.10" SPDriveProp
    VF24DMLT1-GS 24" 1 1 4,854 7.8 Direct 4-Ply
    VF24DMLT3-GS 24" 3 1 4,252 9.0 Direct 3-Glv
    VF30DMLT1-GS 30" 1 1 6,551 10.4 Direct 3-Alm
    VF30DMLT3-GS 30" 3 1 6,645 10.0 Direct 3-Alm
     

    Additional Information

    How To Size Fan & Shutters System?

    1. First thing is to determine is the amount of air required. This is stated in CFM (Cubic Feet of Air per Minute). In addition, the required Air Changes Per Hour (ACH).  A Greenhouse requires 60-120 ACH's depending on location and weather conditions. 
    2. The following formula to determine the CFM's and ACH's required for your greenhouse:
      CFM = Width x Length x Height 
      Example: Greenhouse 12' wide X 40' long X 12' High requires 9,600 CFM at 60 ACH, 14,400 CFM at 90 ACH and 19,200 CFM at 120 ACH. 
    3. Review the above table. Select the appropriate combination of fan(s) to achieve the necessary CFM rating and ACH. Be sure to match the total CFM output for your exhaust fan(s) to the CFM ratings for your Inlet Shutters. Below are examples of end wall to end wall and side wall to side wall ventilation. Call 888-849-1233 for Free Expert Advice. 
     greenhouseventilation.jpg           sidewallwetwallandexhaustgreenhouse.png
     
    Call 888-849-1233 for Free Expert Advice and Factory Direct Pricing
     
View AllClose

12 Reviews

  • 5
    Profitable Cannabis Growing

    Posted by Ed M on 3rd Aug 2019

    We chose the J&D Light Deprivation Exhaust Fans because they are a crucial part of a greenhouse light deprivation system for healthy and profitable blooms. We also want to thank Mike at Factory Fans Direct for his expert advice and the time he spent with our team.

  • 5
    Flower Grower | Needed Light Dep Fans

    Posted by Barry J on 27th Jul 2019

    We are a commercial flower grower and wanted a high quality Light Dep exhaust system. We choose J&D and are very pleased.

  • 5
    Perfect for Growing Cannabis

    Posted by Jack C on 22nd Jul 2019

    We were looking for exhaust fans that had light traps and the J&D 's were perfect for our needs. 5 Stars*****

View AllClose